Handgrip maneuver and pseudonormal transmitral flux pattern in young patients with a structurally healthy heart
Keywords:
Handgrip maneuver, transmitral flow, youth, heart, diastolic functionAbstract
Transmitral flow, although its single modification no longer represents a criteria to define diastolic dysfunction, remains the first step for diagnosis. The pseudonormal pattern remains a challenge in terms of its differentiation with the normal or abnormal pattern in the population, however it is interesting to know the prevalence of this pattern in young populations with structurally healthy heart. We performed a descriptive transversal study in 38 patients with a structurally healthy heart and no known cardiovascular disease, who attended the Regional Cardiovascular Center ASCARDIO in the period January-March 2019. A transthoracic echocardiogram was performed where baseline determinations of transmitral flow and subsequent to the application of the Handgrip maneuver were made. The results show that 68% of patients had a pseudonormal pattern of transmitral flow. After performing the Handgrip maneuver, 84% of the individuals showed a normal flow pattern while 6% had a pseudonormal pattern, with an equal distribution by sex. Handgrip maneuver is useful to unmask the pseudonormal to normal pattern of transmitral flow and in the opposite direction, in patients with structurally healthy heart.
Downloads
References
2. Brutsaert D, Sys S, Gillebert T. Diastolic failure: pathophysiology and therapeutic implications. J Am Coll Cardiol 1993; 22: 318-25.
3. Nagueh S, Smiseth O, Appleton C, Byrd B, Dokainish H, Edvardsen T, et al. Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr 2016; 29: 277-314.
4. Hurrell D, Nishimura R, Ilstrup D, Appleton C. Utility of preload alteration in assessment of left ventricular filling pressure by Doppler echocardiography: a simultaneous catheterization and Doppler echocardiographic study. J Am Coll Cardiol 1997; 30.
5. Jake S, Rhys B, Haykowsky M, Satya S, Suwon P, Dombrowsky T, Bhella P, et al. Isometric handgrip echocardiography: A noninvasive stress test to assess left ventricular diastolic function. Clinical Cardiology. 2017; 1–9.
6. Manolas J. Ischemic and Non ischemic Patterns of Diastolic Abnormalities during Isometric Handgrip Exercise. Cardiology 1995; 86:179-188.
Published
How to Cite
Issue
Section
Derechos del/de autor/es a partir del año de publicación
Esta obra está bajo la licencia:
Creative Commons Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional (CC BY-NC-SA 4.0)
Las opiniones expresadas por los autores no necesariamente reflejan la postura del editor de la publicación ni de la UCLA. Se autoriza la reproducción total o parcial de los textos aquí publicados, siempre y cuando se cite la fuente completa y la dirección electrónica de esta revista. Los autores(as) tienen el derecho de utilizar sus artículos para cualquier propósito siempre y cuando se realice sin fines de lucro. Los autores(as) pueden publicar en internet o cualquier otro medio la versión final aprobada de su trabajo, luego que esta ha sido publicada en esta revista.