Comparative analysis of the structural design of a regular and irregular building of eight levels in a ports system applying standard E.030 2003, 2016 and 2018 seismic resistant design in the city of Lima

Authors

DOI:

https://doi.org/10.51372/gacetatecnica231.5

Keywords:

standard E.030, cocomparative seismic analysis, structural design

Abstract

The comparative analysis of the E.030 2003, 2016 and 2018 seismic design standards is presented, in a study of structures using the portal system for office use in the city of Lima, it focuses on the comparison of vibration periods, percentage of participatory mass, design spectrum, mezzanine distortion, static basal shear force, dynamic and maximum design forces (bending, shear and axial moment), modeled using Etabs 17 software. The regular structure presented variation of 12.50% of static shear and 12.20% for the dynamic analysis according to the 2003 standard compared to 2016 - 2018 and the irregular structure varies by 50% according to the 2003 standard compared to 2016, also a variation of -16.67 % between the 2016 and 2018 norm directly affected by the irregularity changes. The 2018 standard has intermediate results considering modal periods for both structures through static and dynamic analysis.

Downloads

Download data is not yet available.

Author Biographies

Jorge Eduardo De La Cruz Alvarez, Universidad Peruana Unión

Jorge Eduardo, De La Cruz Alvarez. Student in Civil Engineering Universidad Peruana Unión. Lima Peru. Email: jorgedelacr

Roberto Roland Yoctun Rios, Universidad Peruana Unión

Roberto Roland, Yoctun Rios. Research Advisor Professional School of Civil Engineering. Peruvian Union University. Lima Peru. Email: robertoyoctun@upeu.edu.pe

References

J. Yepez, “Desempeño sismico de edificaciones esenciales,” Propues. Vis. 2000, no. 65, pp. 65–86, 1996.

C. Condori y H. Tavera, “Areas probables de ruptura sísmica en el borde occidental del perú, a partir de la variación del parámetro ‘b,’” Soc. Geol. del Perú SGP, vol. 36, no. 1997, pp. 23–36, 2006.

N.T.E, “Norma técnica de edificación,” Sencico, pp. 1–45, 2003.

R.N.E, “Decreto supremo n ° 002-2014-vivienda,” Sencico, 2016.

R.N.E, “RM-355-2018-VIVIENDA (2).pdf,” Sencico, 2018.

S. Hampshire De C. Santos, L. Zanaica, C. Bucur, and S. De Souza Lima, “Comparative Study of Codes for Seismic Design of Structures,” Math. Model. Civ. Eng., vol. 9, no. 1, pp. 1–12, 2013.

J. L. C. Aedo and J. E. A. Hurtado, “Peligro sísmico en el perú,” Peligro Sism. En El Peru, no. 1, p. 19, 1993.

C. Aksoylu, A. Mobark, M. H. Arslan, and I. H. Erkan, “A comparative study on ASCE 7-16, TBEC-2018 and TEC-2007 for reinforced concrete buildings,” Rev. la Constr., vol. 19, no. 2, pp. 282–305, 2020.

C. Zajac and D. Todd, “A Comparative Analysis for Base Shear Calculations between Six Countries With Moderate Seismic Activity,” AEI, pp. 567–580, 2015.

R. Salinas Basueldo, “Fundamentos Del Analisis Dinamico De Estructuras,” Univ. Nac. ed Ing., pp. 1–24, 2013.

A. Jorge, M. Jorge, M. Jose, and H. Carlos, “Avances en la microzonificacion sismica de lima, perú,” CISMID, vol. 1, p. 12, 1991.

H. J. Maco Sarmiento, “Análisis y diseño de una edificación multifamiliar de siete pisos con muros de ductilidad limitada (tesis de titulación),” Pontif. Univ. Católica del Perú, 2014.

NTE E.060, Reglamento Nacional de Edificaciones. Norma E.060 Concreto Armado. 2016.

NTE E.050, “Suelos Y Cimentaciones,” El Peru., pp. 22–68, 2018.

J. Landingin, H. Rodrigues, H. Varum, A. Arêde, and A. Costa, “Comparative Analysis of RC Irregular Buildings Designed According to Different Seismic Design Codes,” Open Constr. Build. Technol. J., vol. 7, no. 1, pp. 221–229, 2014.

R. Medina, “Determinación del nivel de desempeño de un edificio habitacional estructurado en base a muros de hormigón armado y diseñado según normativa chilena,” Obras y Proy., no. 23, pp. 63–77, 2018.

Published

2022-01-30

How to Cite

De La Cruz Alvarez, J. E., & Yoctun Rios, R. R. (2022). Comparative analysis of the structural design of a regular and irregular building of eight levels in a ports system applying standard E.030 2003, 2016 and 2018 seismic resistant design in the city of Lima. Gaceta Técnica, 23(1), 48-71. https://doi.org/10.51372/gacetatecnica231.5

Issue