Structural adequacy for residential complex in Barquisimeto city. Venezuela

Authors

  • José Yepéz Universidad Federal de Rio Grande del Sur. Brasil
  • María Ysabel Dikdan Jaua Universidad Centroccidental Lisandro Alvarado. Venezuela
  • Denis Avon Universidad Centroccidental Lisandro Alvarado. Venezuela
  • Rosangel Rojas de Yepez Universidad Federal de Rio Grande del Sur. Brasil

DOI:

https://doi.org/10.13140/RG.2.2.24818.91841

Keywords:

structural vulnerability, earthquake

Abstract

The structural analysis and reinforcement project is presented for a city complex consisting of 31 houses with obvious signs of failure, built in the city of Barquisimeto in 2008 on unconstrained land. The results of the analysis showed insufficient responsiveness to service stresses, high seismic vulnerability, and deficiencies in the amount and distribution of reinforcing steel. The reinforcement of the superstructure was proposed by means of the construction of panel walls, and micro piles and / or reinforced solid slab for the infrastructure, using values of resistance of the concrete obtained in the destructive tests, soil parameters from the geotechnical study and the settlements Differentials derived from topographic leveling.

Downloads

Download data is not yet available.

Author Biographies

José Yepéz, Universidad Federal de Rio Grande del Sur. Brasil

Investigador Universidad Federal de Rio Grande del Sur (UFRGS), Laboratorio de Ensayos y Modelos Estructurales (LEME), Campus do Vale, Porto Alegre, Brasil. Correo: jose.yepez@ufrgs.br

María Ysabel Dikdan Jaua, Universidad Centroccidental Lisandro Alvarado. Venezuela

Docente Investigadora de la Universidad Centroccidental Lisandro Alvarado. Ingeniero Civil. Doctorado en Seguridad, Calidad y Optimización de Recursos de Infraestructura y su Relación Medioambiental, Universidad de Granada. Presidencia de ALCONPAT Venezuela. Correo: mydikdan@ucla.edu.ve

Denis Avon, Universidad Centroccidental Lisandro Alvarado. Venezuela

Docente investigador de la Universidad Centroccidental Lisandro Alvarado. Mgs. ingeniería estructural. Correo: davon@ucla.edu.ve

Rosangel Rojas de Yepez, Universidad Federal de Rio Grande del Sur. Brasil

Investigadora Universidad Federal de Rio Grande del Sur (UFRGS), Laboratorio de Ensayos y Modelos Estructurales (LEME), Campus do Vale, Porto Alegre, Brasil. Correo: rosangel.rojas@ufrgs.br

References

[1] P. Montilla y A. Castillo, “Vulnerabilidad sísmica de centros poblados. Un caso de estudio: sector Pan de Azúcar, Mérida. Estado Mérida-Venezuela”. Revista Geográfica Venezolana, vol. 53, p. 277-295, 2011
[2] J. Yepez, M. Dikdan, R. Rojas, “Proyecto de Rehabilitación Ampliación de la Emergencia Fundación Augusto Reyes Flores” Informe Inédito, Cruz Roja Seccional Lara, Barquisimeto, 2010.
[3] J. Yepez, M. Dikdan, L. Andrade, R. Rojas, “Adecuación Estructural para la E. B. Jose Felipe Márquez”. Memorias del CONPAT 2015. XIII Congreso Latino-Americano de Patologia da Construção. XV Congresso de Controlo de Qualidade na Construção. Construção 2015. Congresso Luso-Africano da Construção, Instituto Superior Técnico (IST). Lisboa, Portugal, September 2015
[4] J. Yepez, M. Dikdan, L. Andrade, R. Rojas, “Adecuación Estructural para la E. B. Samuel Darío Maldonado” Informe Inédito. Federación de Edificaciones y Dotaciones Educativas FEDE, Caracas, 2011
[5] J. Yepez, M. Dikdan, D. Avon, “Adecuación estructural torre III Conjunto Residencial el Sisal, Barquisimeto, estado Lara, Venezuela”. Memorias del XII Congreso Latinoamericano de Patología y Congreso de Calidad en la Construcción ConPat 2013, Cartagena de Indias, Colombia, September 2013.
[6] L. Morales y J. Contreras, “Protección de una edificación existente con disipadores de energía”, Directores: Juan Alejandro Muñoz Peláez y Marcos Tinman Behar, Pontificia Universidad Católica del Perú, Facultad de Ciencias e Ingeniería, 2012.
[7] F. Da Casa, E. Echeverria y F. Celis, “El movimiento en la ejecución de recalces con inyección armada. Análisis de tres casos con movimientos previos”. Informes de la Construcción,Vol. 64, 528, 507-518, 2012.
[8] M. Dikdan, J. Yepez, D. Avon, R. Rojas, “Diagnóstico Patológico Urb. Villas Lomas del Cercado. Barquisimeto” Informe Inédito. Banco Occidental de Descuento BOD, Caracas, 2013.
[9] Ley del Subsistema de Vivienda y Política Habitacional 10/1999, 5 de octubre, de la Gaceta Oficial de la República de Venezuela, núm.37.066, p.24. 30 de octubre del 2000, Recuperado de: http://historico.tsj.gob.ve/gaceta/octubre/301000/301000-37066-01.html
[10] M. Pardo, Evaluación de Patología Informe Preliminar. Barquisimeto, p. 79, 2011
[11] Norma Venezolana Covenin-Mindur. Método para la Extracción y Ensayo de Probetas Cilíndricas y Viguetas de Concreto Endurecido. 345-80. Caracas: Fondonorma, 1980, Recuperado de: http://www.sencamer.gob.ve/sencamer/normas/345-80.pdf
[12] L. Andrade, M. Sánchez, ʺEstudio Geotécnico Desarrollo Habitacional Villas Lomas del Cercadoʺ. Informe Inédito. Banco Occidental de Descuento BOD, p. 36, Caracas, 2011
[13] Norma Venezolana Covenin–Mindur. Proyecto y Construcción de Obras en Concreto Estructural. 1753-06. Caracas: Fondonorma, 2006, Recuperado de: http://www.inti.gob.ar/cirsoc/pdf/estructuras_hormigon/20327900-COVENIN-1753-2006.pdf
[14] Norma Venezolana Covenin–Mindur. Criterios y Acciones Mínimas para el Proyecto de Edificaciones. 2002-88. Caracas: Fondonorma, 1988, Recuperado de: http://www.sencamer.gob.ve/sencamer/normas/2002-88.pdf
[15] Norma Venezolana Covenin–Mindur. Fondonorma. Edificaciones Sismoresistente. 1756-01. Caracas: Fondonorma, 2001, Recuperado de: http://www.sencamer.gob.ve/sencamer/normas/1756-01.pdf
J. Yépez, M. Y. Dikdan, D. Avon, R. Rojas

Published

2016-12-01

How to Cite

Yepéz, J., Dikdan Jaua, M. Y., Avon, D., & Rojas de Yepez, R. (2016). Structural adequacy for residential complex in Barquisimeto city. Venezuela. Gaceta Técnica, 16(1), 45-60. https://doi.org/10.13140/RG.2.2.24818.91841

Issue

Section

Research articles